5850 Series - Concealed Vertical Rod


5850S 5850F

Concealed Vertical Rod Exit Device

5850S Panic-Rated CVR Exit Device

5850F Fire-Rated CVR Exit Device

5850 series are concealed vertical rod exit devices to be used on single or double metal doors only up to 8' where two-point latching are required. 5850 Series are available in a variety of finishes to match any design style.

 

Certifications

UL Listed: UL listed as Panic Exit Hardware or 3-hour Fire Exit Hardware

ASNI Certified: Devices are ANSI A156.3-2008, Grade 1

 

Applications

  • Panic CVR exit devices are used on single or double metal doors. Fire CVR exit devices are used for UL listed fire labeled pairs of steel doors up to 8' x 8' (2438mm x 2438mm).
  • The exit devices are available in the following finishes: US3, US4, US10, US10B, US26, US26D and US32D.
  • These CVR models cannot be omitted the bottom rod to use as Less Bottom Rod (LBR) devices.

  • Designed for wide stile doors
  • High shock-resistant latching mechanical design for protection from vandalism
  • All inside components are made of high rust-resistant alloy or heavily electroplated steel, no corrosion is concerned
  • Baked powder coating, electroplated, or architectural base material finish on all exposed surfaces are available for users choice

Device Lengths:          Short (36"): 33-15/32" (850mm),

                                      Long (48"): 44-3/4" (1137mm)

Door Widths:                36" - For 29" to 36" (736mm to 914mm) door size

                                       48" - For 33" to 48" (838mm to 1219mm) door size

Minimum Stile Width:   4-1/4" (107mm)

Latch Bolts:                   Top Latch - 5/8" (16mm) throw, can be deadlocked automatically

                                        Bottom Latch - 5/8" (16mm) throw, held retracted during door swing

Strikes:                           Top - 813 (panic), 823 (fire). Bottom - 815 (panic), 825 (fire)

Dogging Kit:                  Panic device - Hex key dogging (RD) standard

                                        Fire device - Sex nuts and bolts (SNB) supplied standard

Dogging Options:         Cylinder Dogging (CD)

                                        Less Dogging (LD)

Mounting Fasteners:    Panic device - Machine screws furnished standard

                                        Fire device - Sex nuts and bolts (SNB) supplied standard

Mounting Height:          Device centerline from finished floor is 40" (1016mm) standard

Door Opening Height:   Standard door height is 7', 8' is available

Vertical Rods:                 1/2" (13mm) diameter tubular

                                        Top rod has two pieces to connect for accommodation 7' or 8' door

                                        Bottom rod is one piece , its length is 31-1/4" (794mm)

Projection:                     Push bar Neutral: 3-1/16" (78mm),

                                        Push bar Depressed: 2-19/32" (66mm)

Description Files Download
EXIT DEVICE CATALOG Exit Device